StiffClip® WC Web Member Connector

 
Product Application

StiffClip® WC connects truss framing web members to chord members. Clip sizes vary with each application. Guide holes are provided in each StiffClip WC for accurate fastener placement. Design loads consider loads on the clip only. Size and number of fasteners used is based on fastener manufacturer’s allowable load data.

 

Material Composition

Steel: ASTM A653/A653M, Grade 40 (275), 40ksi (275MPa) minimum yield strength, 55ksi (380MPa) minimum tensile strength, G-90 (Z275) hot-dipped galvanized coating for 54mil. Grade 50 (340), 50ksi (340MPa) minimum yield strength , 65ksi (450MPa)minimum tensile strength, G-90 (Z275) hot-dipped galvanized coating for 118mil.

Available Thicknesses

Mils
Gauge
Decimal (in)
54
16
0.0566
118
10
0.1242
StiffClip WC Nomenclature

StiffClip WC is designated by multiplying stud depth in inches by 100, then listing material thickness and length.

Example: WC350-54mil 10”

WC = StiffClip WC
350 = Stud depth of 3½” (x100)
54mil = Steel thickness
10” = Length of clip

Back to top ^

StiffClip WC1 StiffClip WC2
StiffClip WC3 StiffClip WC4
StiffClip WC5
  Quantity / Order Information 
Designation
Qty / Box
Lbs / Box
Pcs / Skid
Lbs / Skid
WC350-54mil, 10"lg
100
62
4500
2790
WC350-118mil, 10"lg
50
70
2250
3150
WC550-54mil, 13"lg
50
69
1600
2208
WC550-118mil, 13"lg
25
78
800
2496
WC750-54mil, 16"lg
50
92
3000
5520
WC750-118mil, 16"lg
25
81
1500
4860
StiffClip WC Value
  • Stiffened ribs for added strength (use varies with each clip)
  • Guide holes for attachment to framing members (.172” dia.)
  • No time and expense spent cutting steel shapes
  • Structurally load tested
  • Meets all building code criteria
StiffClip WC Installation

  1. Place StiffClip WC at web of each framing member.
  2. Attach StiffClip WC to framing member with required screws through guide holes.
  Allowable Loads  
StiffClip
Allowable
Design Load
(kips)*
WC350-54mil, 10” lg.
1.300*
WC350-118mil, 10” lg.
5.275*
WC550-118mil, 10” lg.
2.530**
WC750-118mil, 10” lg.
1.690**

* Load based on structural test.
** Load based on calculations.

  • Allowable design loads apply to tension or compression on StiffClip WC utilizing the innermost holes provided and indicated on the load direction diagram.
  • Allowable loads have not been increased for wind, seismic, or other factors.
  • All guide holes may not require fasteners. Fastener amount determined by designer.

Back to top ^

Load Direction And Lengths

StiffClip WC Load Direction & Lengths

Back to top ^

  Oct 2008  

 


          Products are available through local distribution.
Build #: 27