StiffClip® JC

The StiffClip® JC series connects floor joists to beams and other structural components while resisting vertical loads. Pre-drilled guide holes and a support flange streamline installation.
Features
  • Joist flange rests on angle leg for fast joist installation
  • Guide holes for attachment to beam and screw placement to member (0.172″ in diameter)
  • Structurally load tested
Order Information

Order Information

Designation Qty/Box Lbs/Box Qty/Skid Lbs/Skid
JC362/400-43 100 21 11,200 2,352
JC362/400-68 100 33 11,200 3,696
JC600-43 100 30 4,500 1,350
JC600-68 100 47 4,500 2,115
JC800-43 100 35 4,500 1,575
JC800-68 100 60 4,500 2,700
JC800-97 50 39 2,250 1,755
JC1000-68 100 73 4,500 3,285
JC1000-97 50 51 2,250 2,295
JC1200-68 50 43 1,600 1,376
JC1200-97 50 60 1,600 1,920
JC1400-68 50 50 1,600 1,600
JC1400-97 50 70 1,600 2,240

 

Nomenclature

StiffClip JC is designated by listing the joist depth in inches, followed by the required clip thickness in mils that will accommodate anticipated loads. (see technical sheet for load tables)

Example: 6″ joist, 3,000 lbs. load
Designate: StiffClip® JC600-68

Material Composition
ASTM A1003/A1003M Structural Grade 50 (340) Type H, ST50H (ST340H): 50ksi (340MPa) minimum yield strength, 65ksi (450MPa) minimum tensile strength, with ASTM A653/A653M G90 (Z275) hot dipped galvanized coating.
Catalogs
TSN’s Product Catalogs are an essential resource for the design of cold formed steel. Developed by Engineers, the catalogs contain design data for members, connectors, and fasteners. StiffClip® JC can be found in the following Catalogs:

TSN Cold-Formed Steel Framing Connections Order Catalog

TSN Connections Technical Catalog

TSN Cold-Formed Steel Framing Connections Technical Catalog

TSN Connections Order Catalog

For a full list of our product catalogs, specification sections, inspection checklists, and research reports please click here.

StiffClip® JC Downloads

StiffClip® JC Applications

StiffClip JC - Joist Clip - Application

Cold-formed Steel Joist Hanger

Installation Instructions

  1. Attach one angle of StiffClip JC to floor beam through guide holes with approved number of screws.
  2. Place floor joist over StiffClip JC. Attach joist to clip with approved number of screws.

Allowable Loads

F3 Load Direction
JC362/400-43 JC362/400-68 JC600-43 JC600-68 JC800-43 JC800-68 JC1000-68
Screw Patterns with #12 Screws 3 screws 3 screws 3 screws 5 screws 3 screws 5 screws 4 screws 7 screws 4 screws 7 screws 5 screws 9 screws
33mil (20ga), 33ksi Stud 564 564 543 880 543 880 734 1,267 734 1,267 N/A N/A
33mil (20ga), 50ksi Stud 816 816 786 1,273 786 1,273 1,061 1,833 1,061 1,833 N/A N/A
43mil (18ga), 33ksi Stud 836 840 809 1,311 809 1,311 1,093 1,887 1,093 1,887 1,376 2,459
43mil (18ga), 50ksi Stud 836 1,215 1,170 1,896 1,580 2,729 1,580 2,729 1,580 2,729 1,990 3,556
54mil (16ga), 33ksi Stud 836 1,182 1,138 1,845 1,138 1,845 1,538 2,655 1,538 2,655 1,936 3,460
54mil (16ga), 50ksi Stud 836 1,482 1,643 2,158 1,643 2,664 2,220 3,220 2,220 3,834 2,796 4,996
68mil (14ga), 50ksi Stud 836 1,482 1,646 2,158 2,071 3,357 2,224 3,220 2,798 4,617 3,524 5,062
97mil (12ga), 50ksi Stud 836 1,482 1,646 2,158 2,071 3,357 2,224 3,220 2,798 4,617 3,524 5,062
Max Allowable Clip Load 836 1,482 2,158 3,639 3,220 4,617 5,062

 

F3 Load Direction
JC1200-68 JC1400-68 JC1600-68
Screw Patterns with #12 Screws w/6 #12 screws w/11 #12 screws w/7 #12 screws w/13 #12 screws w/8 #12 screws w/15 #12 screws
54mil (16ga), 33ksi Stud 2,334 4,260 2,731 5,057 N/A N/A
54mil (16ga), 50ksi Stud 3,371 5,649 3,944 5,649 N/A N/A
68mil (14ga), 50ksi Stud 4,247 5,649 4,970 5,649 5,649 5,649
97mil (12ga), 50ksi Stud 4,247 5,649 4,970 5,649 5,649 5,649
Max Allowable Clip Load 5,649 5,649 5,649

Notes:

  • Design loads are for attachment of StiffClip JC to joist only. Load tables reflect vertical loads (F3).
  • Design loads consider clip capacity and screw connection to the joist only.
  • All guide holes may not require fasteners. Fastener size and quantity determined by designer.
  • Torsional effects are considered on screw group for F3 allowable loads. It is assumed that half of the torsional moment is resisted by the connection to the structure and half is resisted by the connection to the joist.
  • Allowable loads have not been increased for wind, seismic, or other factors.
  • StiffClip JC attachment to the beam or structure must be designed to be greather than or equivalent to the joist attachment.
  • For LRFD strengths contact TSN technical services.
StiffClip JC - Joist Clip - Load Direction

Load Direction

Follow us on Social Media