VertiClip® SLB
VertiClip® SLB connects exterior curtain wall studs, bypassing the building structure, while allowing for vertical deflection of the structure up to 2” (1” up and 1” down). VertiClip’s unique design provides both an anti-friction and anti-seizure connection between the clip and the stud web surface thereby preventing a transfer of vertical forces into curtain wall framing, which is not engineered to support axial loads. VertiClip SLB eliminates flange-loaded, friction-fit clips, which do not address web-crippling. Allowable loads are based on use of two #12 screws for attachment to stud (provided by TSN). Value
|
US Patents #5,467,566 & #5,906,080 | ||
___________________________________________________________________________________________________________ | |||
An ICC-ES Evaluation Report for VertiClip SLB is available. Click here to view the report |
| Step Bushing Technology | |
___________________________________________________________________________________________________________ | |||
A Los Angeles Research Report for VertiClip SLD, SL, SLB, SLS, and SLT Series is available. Refer to LARR #25631. Click here to view the report. |
| Blast & Seismic Design Data | |
- Application Image
- Installation
- Nomenclature/Order Info
- Allowable Loads
- Material Composition

|
|
|
Quantity/Order Information
|
* Use of strengthening ribs varies with each clip. Each VertiClip SLB contains stiffened ribs in the angle heel. |
||||||||||||||||||||||||||||||||||||||||
|
Nomenclature VertiClip SLB is classified by multiplying stud depth by 100. Example: 6” stud = VertiClip SLB600. The VertiClip SLB600-10 and 600-12 accommodate an even greater construction tolerance of studs from structure and are now standard products. The VertiClip SLB600-10 is 10” in depth with slot spacing designed for a 6” stud, and the VertiClip SLB600-12 is 12” in depth with slot spacing designed for a 6” stud. |
|
The attachment of VertiClip® to the primary structure may be made with a PAF or weld and is dependent upon the base material (steel or concrete) and the design configuration. Allowable load tables incorporate eccentric loading of fasteners. Values with welded connection may increase. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Note:
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Load Direction
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
ASTM A1003/A1003M Structural Grade 50 (340) Type H, ST50H (ST340H): 50ksi (340MPa) minimum yield strength, 65ksi (450MPa) minimum tensile strength, 68mil minimum thickness (14 gauge, 0.0713” design thickness) with ASTM A653/A653M G90 (Z275) hot dipped galvanized coating.
The attachment of VertiClip to the primary structure may be made with a PAF, screw/bolt anchors or weld and is dependent upon the base material (steel or concrete) and the design configuration.