VertiClip® SLD

VertiClip® SLD connects metal studs at the head condition (top of wall) to the deck or primary frame while allowing for a total vertical deflection of up to 1½” (¾” up and ¾” down). VertiClip’s unique design provides both an anti-friction and anti-seizure connection between the clip and the stud web surface thereby preventing a transfer of vertical forces into drywall partition wall framing, which is not designed to support axial loads. VertiClip SLD is a component in VertiTrack® VTD, TSN’s pre-assembled deflection track. Allowable loads are based on use of two #8 screws for attachment to stud (provided by TSN).

Value

  • Load-rated positive mechanical attachment at each stud
  • UL classified for all approved dynamic assemblies and finish combinations with 1½” deflection and 1-2 hour fire-ratings
  • Meets all building code criteria
  • Eliminates loose friction-held track assemblies
  • Utilizes only certified, 50ksi steel
  • Load rated screws provided for each VertiClip
  • Step Bushings pre-installed for accurate placement
  • Adaptable for multiple configurations
  • Top of wall bridging or strapping is eliminated
  • Top track lightweight for easy handling (not a structural element, may be 25ga [interior] or 20ga [exterior] standard leg - Deep-Leg Track is not required)
  • Utilize clips for wall layout
  • Eliminates temporary screws

 

US Patents #5,467,566 & #5,906,080

___________________________________________________________________________________________________________
 
NYC Buildings IconNY MEA-326-06-MBlast & Seismic Design DataBlast & Seismic Design DataStep Bushing TechnologyStep Bushing Technology
___________________________________________________________________________________________________________
ICCAn ICC-ES Evaluation Report for VertiClip SLD600 is available. Click here to view the reportLAA Los Angeles Research Report for VertiClip SLD, SL, SLB, SLS, and SLT Series is available. Refer to LARR #25631. Click here to view the report.ULMeets criteria for: ICC-ES AC261; UL2079; IBC 2000, 2003; DSA, New York MEA 326-06-M.
      
Downloads: Download Technical data Tech Sheet | Download drawing file DWG | Download BIM data BIM
  • Application Image
  • Installation
  • Nomenclature/Order Info
  • Allowable Loads
  • Material Composition
  • When to Use VertiClip® SLD
  • Shaft Wall

Note: Track thickness not limited to 20 gauge.

  1. Attach standard leg runner track to deck.
  2. Attach VertiClip® SLD to deck (through track).
  3. Attach VertiClip® through Step Bushings to wall studs with self-drilling screws provided.

pdf icon Printable Installation Instructions

Quantity/Order Information

Designation
Qty/Box Lbs/Box Pcs/Skid Lbs/Skid
SLD150  250 19 11250 855
SLD250  250 28 11250 1260
SLD362/400  200 35 9000 1575
SLD600  100 28 4500 1260
SLD800  100 37 4500 1665

 

 

 VertiClip SLD Dimensions

Nomenclature

VertiClip® is designated by type (SLD), followed by stud depth in inches multiplied by 100.

Example: 6” deep stud: Designate VertiClip® SLD600

Allowable (Unfactored) Loads1
VertiClip®
Series
Stud Thickness Mils (ga) Fy (yield) Stud (ksi) SLD150 F2 w/ 1 #8 screw (lbs) SLD250 F2 w/ 2 #8 screws (lbs) SLD362 / 400 F2 w/ 2 #8 screws (lbs) SLD600 F2 w/ 2 #8 screws (lbs) SLD800 F2 w/ 2 #8 screws (lbs)

SLD (Clip is 20ga, 33mils)

18 (25)  33 51 132 132 132 132
27 (22)  33 51 159 243 243 243
33 (20)  33 51 159 328 328 328
33 (20)  50 51 159 359 405 474
43 (18)  33 51 159 359 405 489
43 (18)  50 51 159 359 405 664
54 (16)  33 51 159 359 405 664
54 (16)  50 51 159 359 405 664
Maximum Allowable Clip Load 51 159 359 405 682
  • Allowable loads have not been increased for wind, seismic, or other factors.
  • Two #8 screws are provided with each VertiClip® SLD (except SLD150, which has 1 screw).

1 For LRFD Design Strengths refer to ICC-ESR-1903

Note:

Fasten within ¾” from the angle heel (centerline of the 1½” leg) to minimize eccentric load transfer.
Guide holes for attachment to structure are .172” for SLD600 and .141" for SLD362/400, and are not standard for other clip sizes
Deflection requirements greater than ¾” (up and down) are avaiable.

VertiClip SLD series is designed to support horizontal loads and should not be used in axial-load-bearing wall construction.

Load Direction

VertiClip SLD-Load Direction 

ASTM A1003/A1003M Structural Grade 50 (340) Type H, ST50H (ST340H): 50ksi (340MPa) minimum yield strength, 65ksi (450MPa) minimum tensile strength, 33mil minimum thickness (20 gauge, 0.0346” design thickness) with ASTM A653/A653M G60 (Z180) hot dipped galvanized coating.

The attachment of VertiClip to the primary structure may be made with a PAF, screw/bolt anchors or weld and is dependent upon the base material (steel or concrete) and the design configuration.

When to Use VertiClip® SLD and VertiClip® SL
Wind Pressure 20 psf 25 psf 30 psf 40 psf
Deflection Limit L/360 L/600 L/360 L/600 L/360 L/600 L/360 L/600
Stud Spacing
16” o.c. 24” o.c. 16” o.c. 24” o.c. 16” o.c. 24” o.c. 16” o.c. 24” o.c. 16” o.c. 24” o.c. 16” o.c. 24” o.c. 12” o.c. 16” o.c. 12” o.c. 16” o.c.

362/400 Stud Depth

Wall Height 9 ft.  SLD  SLD  SLD  SL  SLD  SLD  SLD  SL  SLD  SLD  SL  SL*  SLD  SLD  SL  SL 
10 ft.  SLD  SLD  SL  SL  SLD  SL  SL  SL*  SLD  SL  SL  SL*  SLD  SL  SL  SL* 
12 ft.  SL  SL*  SL*  SL*  SL  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL* 
15 ft.  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL* 
600 Stud Depth Wall Height 9 ft.  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD 
10 ft.  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD 
12 ft.  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SL  SLD  SLD  SLD  SL 
15 ft.  SLD  SLD  SL  SL  SLD  SL  SL  SL  SLD  SL  SL  SL*  SLD  SL  SL  SL* 
18 ft.  SL  SL  SL  SL*  SL  SL  SL*  SL*  SL  SL*  SL*  SL*  SL  SL*  SL*  SL* 
21 ft.  SL  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL*  SL* 
800 Stud Depth Wall Height 9 ft.  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD 
10 ft.  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD 
12 ft.  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD 
15 ft.  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SLD  SL  SLD  SL  SLD  SLD  SLD  SL 
18 ft.  SLD  SLD  SLD  SL  SLD  SL  SL  SL  SLD  SL  SL  SL  SLD  SL  SL  SL 
21 ft.  SLD  SL  SL  SL*  SL  SL  SL  SL*  SL  SL  SL*  SL*  SL  SL  SL*  SL* 
24 ft.  SL  SL  SL*  SL*  SL  SL*  SL*  SL*  SL  SL*  SL*  SL*  SL  SL*  SL*  SL* 

Important Notes:

  • SLD considered for use on 43 mil or thinner sections
  • A load factor of 0.7 is used for deflection determination
  • SL* means a single standard stud will not work. A wider flange wall stud (2” or 2.5” flange) is needed
  • All Connections an be made with use of 2 screws
 
VertiClip® SLD may be used in shaft wall assemblies to provide a positive attachment at the top of wall. Sizes include VertiClip® SLD150, 250, and 362 for 2.5”, 4”, and 6” shaft wall stud depths.
  VertiClip® SLD is also listed in UL®-Classified WR Grace shaft wall assembly HW-D-0401.