VertiClip® SLT

VertiClip® SLT and SLT(L) slide clips connect exterior curtain wall studs, bypassing the building’s structural concrete slab or structural steel frame, while allowing for a vertical deflection of the structure of 1” (½” up and down for SLT) and 1.875” (0.938” up and down for SLT(L)). VertiClip’s unique design provides both an anti-friction and anti-seizure connection between the clip and stud web surface thereby preventing a transfer of vertical forces into curtain wall framing, which is not engineered to support axial loads. Allowable loads are based on use of #12 screws for attachment to stud (provided by TSN).

Value

  • Positive, load-rated, mechanical attachment to stud web
  • 97 mil (12 Gauge) material
  • Friction-free movement
  • Certified material
  • Eliminates untested “scabs” or shims
  • Step Bushings are taped in place at factory for correct placement
  • Tested screws provided

SLT

US Patents #5,467,566 & #5,906,080

___________________________________________________________________________________________________________
    


An ICC-ES Evaluation Report for VertiClip SLT 9.5 & SLT(L)-18  is available. Click here to view the report

Step Bushing Technology



Step Bushing Technology
___________________________________________________________________________________________________________
    



A Los Angeles Research Report for VertiClip SLD, SL, SLB, SLS, and SLT Series is available. Refer to LARR #25631. Click here to view the report.

Blast & Seismic Design Data




Blast & Seismic Design Data
Downloads: Download Technical data Tech Sheet | Download drawing file DWG | Download BIM data BIM
  • Application Image
  • Installation
  • Nomenclature/Order Info
  • Allowable Loads
  • Material Composition

SLT  

 

SLT(L)

 

 

  1. Attach SLT to top of slab with engineered attachment. Allow 4” minimum clip area for attachment to slab.
  2. Align studs to SLT for plumb wall assembly.
  3. Attach SLT to wall stud with provided screws through Step Bushings.

pdf icon Printable Installation Instructions

Quantity/Order Information

Quantity / Order Information
Designation
Qty/Box Lbs/Box Pcs/ Skid

Lbs/Skid

SLT-9.5  50 47 1600 1504
SLT(L)12  25 43 375 645
SLT(L)15  20 46 300 690
SLT(L)18  20 50 300 750

 

 

 

 

 

 

  • VertiClip® SLT is available in a length of 9 ½”.
  • VertiClip® SLT(L) is available in lengths of 12”, 15”, and 18”.
  • Determine length by adding stud + offset + 3” (for steel, or 5.5” for concrete) and selecting the next largest size.

VertiClip SLT Dimensions

VertiClip SLT(L) Dimensions 

 

Recommended Allowable Loads: F1
Stud SLT-9.5 SLT(L)-12, SLT(L)-15 & SLT(L)-18

Thickness
mils (ga)

Yield Fy (ksi) F1 w/ (2) #12 screws (lbs) F1 w/ (2) #12 screws (lbs) F1 w/ (4) #12 screws (lbs)
33 (20) 33 190 190 380
33 (20) 50 275 275 452
43 (18) 33 248 248 452
43 (18) 50 341 359 452
54 (16) 33 312 312 452
54 (16) 50 341 450 452
68 (14) 50 341 452 452
97 (12) 50 341 452 452
Maximum Allowable Clip Load 341 452

452

Recommended Allowable Loads: F2
Stud SLT-9.5 SLT(L)-12 SLT(L)-15 SLT(L)-18

Thickness
mils (ga)

Yield Fy (ksi) F2 w/ (2) #12 screws (lbs) F2 w/ (2) #12 screws (lbs) F2 w/ (4) #12 screws (lbs) F2 w/ (2) #12 screws (lbs) F2 w/ (4) #12 screws (lbs) F2 w/ (2) #12 screws (lbs) F1 w/ (4) #12 screws (lbs)
33 (20) 33 376 376 754 376 744 376 700
33 (20) 50 510 544 903 544 744 544 700
43 (18) 33 510 560 903 560 744 560 700
43 (18) 50 510 810 903 744 744 700 700
54 (16) 33 510 789 903 744 744 700 700
54 (16) 50 510 903 903 744 744 700 700
68 (14) 50 510 903 903 744 744 700 700
97 (12) 50 510 903 903 744 744 700 700
Maximum Allowable Clip Load 510 903 903 744 744 700

700

  • Allowable loads have not been increased for wind, seismic, or other factors.
  • Two (2) #12 screws are provided with each VertiClip SLT.
  • Four (4) #12 screws are provided with each VertiClip SLT(L).

1 For LRFD Design Strengths refer to ICC-ESR-1903.

 

Load Direction

VertiClip SLT Load Direction

ASTM A1003/A1003M Structural Grade 50 (340) Type H, ST50H (ST340H): 50ksi (340MPa) minimum yield strength, 65ksi (450MPa) minimum tensile strength, 97mil minimum thickness (12 gauge, 0.1017” design thickness) with ASTM A653/A653M G90 (Z275) hot dipped galvanized coating.

The attachment of VertiClip to the primary structure may be made with a PAF, screw/bolt anchors or weld and is dependent upon the base material (steel or concrete) and the design configuration.