VertiClip® SLT

VertiClip® SLT and SLT(L) slide clips connect exterior curtain wall studs, bypassing the building’s structural concrete slab or structural steel frame, while allowing for a vertical deflection of the structure of 1” (½” up and down for SLT) and 1.875” (0.938” up and down for SLT(L)). VertiClip’s unique design provides both an anti-friction and anti-seizure connection between the clip and stud web surface thereby preventing a transfer of vertical forces into curtain wall framing, which is not engineered to support axial loads. Allowable loads are based on use of #12 screws for attachment to stud (provided by TSN).

Value

  • Positive, load-rated, mechanical attachment to stud web
  • 97 mil (12 Gauge) material
  • Friction-free movement
  • Certified material
  • Eliminates untested “scabs” or shims
  • Step Bushings are taped in place at factory for correct placement
  • Tested screws provided

SLT

US Patents #5,467,566 & #5,906,080

Step Bushing Technology
  
___________________________________________________________________________________________________________
ICC

An ICC-ES Evaluation Report for VertiClip SLT 9.5 & SLT(L)-18  is available. 
Click here to view the report

LA

A Los Angeles Research Report for VertiClip SLD, SL, SLB, SLS, and SLT Series is available. Refer to LARR #25631.  Click here to view the report.

Downloads: Download Technical data Tech Sheet | Download drawing file DWG | Download BIM data BIM
  • Application Image
  • Installation
  • Nomenclature/Order Info
  • Allowable Loads
  • Material Composition

SLT  

 

SLT(L)

 

 

  1. Attach SLT to top of slab with engineered attachment. Allow 4” minimum clip area for attachment to slab.
  2. Align studs to SLT for plumb wall assembly.
  3. Attach SLT to wall stud with provided screws through Step Bushings.

pdf icon Printable Installation Instructions

Quantity/Order Information

Quantity / Order Information
Designation
Qty/Box Lbs/Box Pcs/ Skid

Lbs/Skid

SLT-9.5  50 47 1600 1504
SLT(L)12  25 43 375 645
SLT(L)15  20 46 300 690
SLT(L)18  20 50 300 750

 

 

 

 

 

 

  • VertiClip® SLT is available in a length of 9 ½”.
  • VertiClip® SLT(L) is available in lengths of 12”, 15”, and 18”.
  • Determine length by adding stud + offset + 3” (for steel, or 5.5” for concrete) and selecting the next largest size.

 VertiClip SLT Dimensions

VertiClip SLT(L) Dimensions

VertiClip®
Series
Load
Direction
Stud
Thickness
Mils (ga)
Fy (yield) Stud (ksi) F2 w/2
screws (lbs)
SLT 9.5 (Clip is
12ga, 97mils)
F2 33 (20)  33 376
33 (20)  50 510
43 (18)  33 510
43 (18)  50 510
54 (16)  33 510
54 (16)  50 510
68 (14)  50 510
97 (12)  50 510
Maximum Allowable Clip Load

510

VertiClip®
Series
Load
Direction
Stud Thickness Mils (ga) Fy (yield) Stud (ksi) F1 w/2
screws (lbs)
SLT 9.5 (Clip is
12ga, 97mils)
F1 33 (20)  33 190
33 (20)  50 275
43 (18)  33 248
43 (18)  50 341
54 (16)  33 312
54 (16)  50 341
68 (14)  50 341
97 (12)  50 341
Maximum Allowable Clip Load

341

VertiClip®
Series
Load
Direction
Stud Thickness
Mils (ga)
Fy (yield) Stud (ksi) F2 w/2
screws (lbs)
F2 w/4
screws (lbs)
SLT(L) (Clip is 12ga, 97mils) F2 33 (20)  33 376 700
33 (20)  50 544 700
43 (18)  33 560 700
43 (18)  50 700 700
54 (16)  33 700 700
54 (16)  50 700 700
68 (14)  50 700 700
97 (12)  50 700 700
Maximum Allowable Clip Load 700

700

VertiClip®
Series
Load
Direction
Stud Thickness Mils (ga) Fy (yield) Stud (ksi) F2 w/1 screws (lbs) F1 w/4
screws (lbs)
SLT(L) (Clip is 12ga, 97mils) F1 33 (20)  33 190 380
33 (20)  50 275 452
43 (18)  33 248 452
43 (18)  50 359 452
54 (16)  33 312 452
54 (16)  50 450 452
68 (14)  50 452 452
97 (12)  50 452 452
Maximum Allowable Clip Load 452

452

  • Allowable loads have not been increased for wind, seismic, or other factors.
  • Two (2) #12 screws are provided with each VertiClip SLT.
  • Four (4) #12 screws are provided with each VertiClip SLT(L).

1 For LRFD Design Strengths refer to ICC-ESR-1903.

Load Direction

VertiClip SLT-Load Direction

ASTM A1003/A1003M Structural Grade 50 (340) Type H, ST50H (ST340H): 50ksi (340MPa) minimum yield strength, 65ksi (450MPa) minimum tensile strength, 97mil minimum thickness (12 gauge, 0.1017” design thickness) with ASTM A653/A653M G90 (Z275) hot dipped galvanized coating.

The attachment of VertiClip to the primary structure may be made with a PAF, screw/bolt anchors or weld and is dependent upon the base material (steel or concrete) and the design configuration.